A chiller is a system that captures heat from the liquid using the compression refrigeration cycle or the absorption refrigeration cycle. This cooled liquid can be used in air conditioning equipment such as air conditioners and fan coils. Heat derived from water can be used in a given environment or for increased efficiency in heating applications.
You can also make a price as a seller
Request a price to negotiate and get a better offer

Suppliers

SuppliersExpiration datePrice (Toman)Minimum order (MOQ)CityPhone number
The price is not recorded

similar products

Chiller EMICON Mabna

EMICON Chiller Components Specifications:
Body:

The base and chassis of the machine is very thick galvanized steel, which is riveted by stainless steel. The whole body is painted with RAL 7035 coating.

Compressor:
These compressors are equipped with anti-vibration tires, overload protectors and crankcase heaters to prevent the viscosity of the oil and are provided with direct-start motors cooled by suction gas. These compressors are powered by polyester oil and have IP54 protection.


operator:
The evaporator is a type of stainless steel plate converter, with one or two refrigeration cycles and is highly insulated with high-thickness elastomeric foam and can be UV-coated. The maximum operating pressure is 6 bar water and 42 bar refrigerant. The evaporator is fitted with a flowmeter that turns off the device when the evaporator is running low.

Condenser:
The condenser has copper tubes with aluminum microphones. To increase heat exchange, the design of the filters is based on Turbo-fin technology. The maximum relative pressure of the condenser is 45 bar.

Fan:
High-efficiency direct-coupled direct-current fan features aluminum blades with low noise level and IP54 protection class. They are also fitted with overload protection thermostats and galvanized steel gratings.


Refrigeration Cycle:
Each refrigeration cycle is fitted with disconnecting valve for refrigerant charging, anti-freeze sensor, valve disconnecting valve, site glass, drive filter, high pressure safety valve, thermostatic mechanical expansion valve, and pressure gauges and switches. is.


Electrical board:
Manufacture of electrical boards is in accordance with IEC 204-160204-1 / IEC. Electrical board when installing the device outdoors with a protective cabinet, including control and power system, microprocessor electronic board equipped with keypad and display, main lock-type switch, transformer to separate main circuitry from auxiliary circuits Compressors and fans, protection fuses and switches, alarm terminal and on / off system, board terminal, phase sequence relay and interface to BMS system.