Market construction
Market construction

Expansion tank 80litr Mehrafrooz

Mehrafrooz
Iran

When the water temperature drops from 20 ° C to 100 ° C, the volume increases by about 4%; and the pipes and fittings in the pressure piping system are inserted, which is likely to cause the boiler and fluid transmission system to burst. In this case, the safety valve that is installed on the boiler for critical times is activated and drains the excess water. Reliable valves do not have a high safety factor and may not be able to withstand the extra pressure due to the problem. In addition, leaving the heated water out of the system will waste water and energy. It is therefore fitted with a reservoir fluid transfer system that can withstand an increase in the volume of water circulating in the heating system, which is called an expansion source. Another function of the expansion of the hot fluid transmission system is to compensate for the water shortage in the circulation system, which supplies the water required by the system if water is reduced for various reasons, including leakage. Therefore, the expansion source in addition to connecting the circulating water to the heating system is connected to a municipal water inlet valve with a float.
You can also make a price as a seller
Request a price to negotiate and get a better offer

Suppliers

SuppliersExpiration datePrice (Toman)Minimum order (MOQ)CityPhone number
The price is not recorded

similar products

Expansion tank 80litr Mehrafrooz

The open-air source is, as can be seen from the illustration, a reservoir that is connected to the open air and exterior air pressure is applied to the surface. To prevent water overflow and to regulate system pressure, an open expansion source is installed above the top radiator (generally on the roof). Open expansion sources are used for low-pressure central heating systems with a maximum temperature of 180 degrees Fahrenheit. How Open Source Source Works As noted above, as the volume of water circulating in the central heating system increases as the temperature rises, the water level in the open expansion spring rises and the static pressure equals the height of the source relative to the boiler. This pressure applies to all the water in the thermal installation system and causes the water to rise from the pipes of the transmission system. For this reason, the open source should always be mounted at a height (at least 2 meters) above the highest radiator. The open expansion source also controls the amount of water in the cycle through the mains water pipe and by the float therein, so that in the event of any leakage in the installation cycle that reduces the volume of water in the expansion source, Adding municipal water as much as the output of the cycle, the amount of cycle water remains constant. How to install open source expansion The connection of the open expansion source to the central heating system is accomplished through two circular pipes to the circulating water transfer system. The reason for installing a round pipe to these sources is the circulation of hot water in these tanks. Because open source water is exposed to cold winter weather, there is a possibility of freezing of water in the reservoir and preventing hot pot circulation in the reservoir. In addition to these two circulating pipes, open expansion springs are also connected to municipal water to compensate for the water shortage required by a floating valve.

Product Specifications

Body Material
Insulated black sheet
Source weight (kg)
11
Source length (cm)
50
Source diameter (cm)
53.5
Capacity (liters)
80
Insulation
has it

User's comments and scores